Technical Information / Datasheet
EtherCAT Bus module SK TU4-ECT-C
1.1 LED - displays, technical datas, Error 10.9 4913 Rck TI 275281167 GB
version reason for change(s) issue name document speech
Pos: 4 /T echnis che Inf orma tion en/SK xU x - Bus - E rwei ter ung en/ Eth erC at/S K TU 4-EC T-C / 27 528 116 7 / B asis i nfor mati one n [S K TU 4-EC T-C] @ 3\ mod_1371720846473_388.docx @ 79011 @ 555 @ 1
SK TU4-ECT-C
Part number: 275 281 167
EtherCAT® - External bus interface
NOTICE
Validity of the documents
This document is only valid in combination with the operating instructions for the relevant frequency inverter. All
of the information that is relevant for a safe start-up of this module and the frequency inverter is only available
under these conditions.
Scope of supply
1 x Module SK TU4-ECT-C
4 x Hexagon socket M4 x 40 mm
Accessories required:
1 x Bus connection unit SK TI4-TU-BUS-C
TI 275280500 Part No. 275 280 500)
Field of use
External technology unit for connecting a decentralised frequency inverter (SK 180E … SK 2xxE) to
an EtherCAT field bus. The module can be fitted to or in the immediate vicinity of the frequency
inverter. It is connected to the inverter via the system bus, and can communicate directly with up to 4
frequency inverters. 8 digital inputs and 2 digital outputs are available.
Technical Data
Module
Temperature range -25 °C … 50 °C Vibration resistance 3M7
Temperature class Class 3k4 Firmware version V1.6 R1
Protection class IP66 Hardware version BB
Supply voltage 24 V ± 20 %, ≈ 100 mA
Reverse polarity protected
Dimensions [mm]* H x W x D: 95 x 136 x 99
* module fitted to BUS-connection unit
Depth: 108mm with covers on M12-connection
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - SK TU4-ECT-C

Technical Information / Datasheet EtherCAT Bus module SK TU4-ECT-C 1.1 LED - displays, technical datas, Error 10.9 4913 Rck TI 275281167 G

Page 2

EtherCAT Bus module – SK TU4-ECT-C 2 TI 275281167 - 4913 Digital input - working area Low: 0 V … 5 V, High: 15 V … 30 V Digital input - specif

Page 3

EtherCAT Bus module – SK TU4-ECT-C TI 275281167 - 4913 3 Connections The two Ethernet lines are connected exclusively via the two M12 sockets

Page 4 - 4 TI 275281167 - 4913

EtherCAT Bus module – SK TU4-ECT-C 4 TI 275281167 - 4913 Schematic diagram - electrical connection (Terminal designation on example of NORD fre

Page 5 - = 0.5 s on / 1 s off

EtherCAT Bus module – SK TU4-ECT-C TI 275281167 - 4913 5 EtherCAT-specific LEDs RUN State Meaning OFF Init • No communication of process da

Page 6 - 6 TI 275281167 - 4913

EtherCAT Bus module – SK TU4-ECT-C 6 TI 275281167 - 4913 Error messages Error messages from the module - present errors or archived messages r

Page 7 - TI 275281167 - 4913 7

EtherCAT Bus module – SK TU4-ECT-C TI 275281167 - 4913 7 Parameters Frequency inverter: The following frequency inverter parameters must be a

Page 8

EtherCAT Bus module – SK TU4-ECT-C 8 TI 275281167 - 4913 Parameter access and diagnosis The NORD CON software and optional control units such